For MGS side obstacle protection on a divided highway, what is your suggested practice for transitioning from standard post spacing to quarter post spacing?  Would you mirror the transition on the downstream side, even though this is a one-way situation?

 

 



Road Closure Gates
Thrie Beam Guardrails



Date December 14, 2011
Previous Views (149) Favorites (0)
Response
Response
(active)

Could you clarify the sentence highlighted below?  I'm having trouble following.  Also, how far upstream of the obstacle would you recommend the quarter-post spacing begin?

 

Thus, MwRSF has suggested that rail splices be configured to occur a minimum of 1 reduced span (3 ft - 1½-in.), and preferably 2 reduced spans (6 ft " 3in.), beyond the last or first MGS full-post spacing.

 


Date December 15, 2011
Previous Views (149) Favorites (0)
Response
Response
(active)

 

 

The quarter-post spacing MGS should begin a minimum longitudinal distance of approximately 12 ft " 6 in. in advance of the hazard.

 

In terms of rail splices locations, numerous rail splices occur at mid-span locations within the full-post spacing MGS. However, there will be a post where full-post spacing ends and half-post spacing begins. We are suggesting a preference to not locate a rail splice at this transition post. Instead, we would prefer that the first rail splice within the half-post spacing region occur either 1 or 2 posts away from where full-post spacing ends. I hope that this helps to clarify the issue.  