Question
State WY
Description Text
Hi Bob,
I have a question about the standardized buttress. The stirrups are only extending below the buttress by 6 inches for embedment into a concrete slab. That doesn't appear to be adequate to develop the full strength of the stirrups and to resist overturning. Do you have additional details on how this would connect to the concrete slab below?


Approach Guardrail Transitions (AGTs)



Date December 10, 2018
Previous Views (148) Favorites (0)
Attachment AGT Buttress_R10 (1).pdf
Response
Response
(active)

The details shown in our cad are only for anchorage to our tarmac and do not represent what would be used in a bridge deck.

 

I have copied Scott on this. He did the development work on the buttress and may be able to guide you on the tie into a bridge deck. It would likely depend on the deck in question, but is mostly a question of achieving appropriate development of the anchor bars.


Date December 11, 2018
Previous Views (148) Favorites (0)
Response
Response
(active)

 

You are correct.  The 6” embedment by itself is not sufficient to fully develop the stirrups.  The simplest thing to do would be to put a 90 degree bend in the front leg of the stirrup and tie it into the lower mat of steel in your concrete slab.  Unfortunately, we don’t have anything sketched up showing these bars fully anchored to a slab right now.


Date December 12, 2018