Question
State UT
Description Text
Contractors are
asking if they can use two 8 inch blocks in place of a 12 inch block placed on
the CRT posts within the long span.  Would this be acceptable?


Road Closure Gates
Thrie Beam Guardrails



Date February 28, 2017
Previous Views (69) Favorites (0)
Response
Response
(active)

In the metric-height W-beam long span guardrail, MwRSF incorporated the use of double, 8-in. deep wood blockouts with the three CRT posts adjacent to the long span.

 

Thus it would seem reasonable that similar double 8” deep blockouts would be acceptable for use on the CRT posts in the MGS long span.

 

Alternatively, you could use an 8” and a 4” block if you wanted to preserve the 12” depth of the tested system.

 